 ^Warranty ​    ​|Two-Year Parts and Labor Warranty ​    ​|Unknown ​    ​|Unknown ​    |One Year Parts and Labor Warranty ​    | ^Warranty ​    ​|Two-Year Parts and Labor Warranty ​    ​|Unknown ​    ​|Unknown ​    |One Year Parts and Labor Warranty ​    |
 ^Air circulation ​    ​|"​Forced air mechanical convection - horizontal air flow; a 3.3 cm (1.3""​) stainless steel ventilation cap" ​    ​|Mechanical convection technique; top mount fan with diffuser panel for gentle circulation of air inside chamber ​    ​|Adjustable fan speed ; No condensation will appear in the inner chamber during cooling ​    ​|"​Directed airflow system; forced air from right to left (more efficiently maintains a uniform temperature as opposed from top to bottom)" ​    | ^Air circulation ​    ​|"​Forced air mechanical convection - horizontal air flow; a 3.3 cm (1.3""​) stainless steel ventilation cap" ​    ​|Mechanical convection technique; top mount fan with diffuser panel for gentle circulation of air inside chamber ​    ​|Adjustable fan speed ; No condensation will appear in the inner chamber during cooling ​    ​|"​Directed airflow system; forced air from right to left (more efficiently maintains a uniform temperature as opposed from top to bottom)" ​    |
-^Doors ​    |Two doors (outer one solid; inner one tempered glass door)     |One door solid or glass     ​|"​Two ​glass doors     | (Inner glass door)" ​    |One glass     | +^Doors ​    |Two doors (outer one solid; ​the inner one tempered glass door)     |One door solid or glass     ​|"​Two doors (Inner glass door)" ​    |One glass     | 
-^Over-temperature protection ​    ​|Over-temperature and over-current protection by sensor error detection ​    ​|Built-in high temperature safety ​    ​|"​Independent adjustable temperature safety device class 3.1     | providing full protection against chamber over-temperature ​    | with visual and audible temperature alarm" ​    ​|Temperature safety: Sensor & Controller by Thermostat with audible/​visual alarm     |+^Over-temperature protection ​    ​|Over-temperature and over-current protection by sensor error detection ​    ​|Built-in high temperature safety ​    ​|"​Independent adjustable temperature safety device class 3.1 providing full protection against chamber over-temperature with visual and audible temperature alarm" ​    ​|Temperature safety: Sensor & Controller by Thermostat with audible/​visual alarm     |
 ^Exterion construction ​    ​|Powder-coated steel exterior ​    ​|Powder-coated steel exterior ​    ​|Unknown ​    |18 gauge cold-rolled steel powder coated ​     | ^Exterion construction ​    ​|Powder-coated steel exterior ​    ​|Powder-coated steel exterior ​    ​|Unknown ​    |18 gauge cold-rolled steel powder coated ​     |